Draw a heating system
with separate water storage on a DIN A4 paper in landscape format. The system
should be a weather-led system with automatically adjusting boiler temperature
control and with storage priority circuit/switching. The heat exchangers that
exist in the house are equipped with thermostats. The system should be installed
without mixer. Use your table book or manufacturer brochures in order to determine
the device mass.
Consider all necessary
components and parts in your drawing.
Also plan and draw in
the connection of the regulation and control unit to the heating system circulation
as well as to the storage system circulation and to all other necessary components.
10. Particularities of the exhaust gas system/transport
Exercise 10
Explain the differences
between exhaust gas systems for room air dependently operating gas devices
and room air independently operating gas devices.